Follow us :

How to use wire mesh machine?

1.Wire mesh welding machine can only be welded after passing water. The active parts of the welder should always be lubricated, the weldment should be cleaned after cleaning, so as not to damage the electrode or affect the welding electrode life.

2. When the wire mesh welding machine working at temperatures below zero degrees Celsius,welding should be completed after the use of compressed air to remove the remaining cooling water in the cooling pipe, so to prevent water pipes and welding transformers frozen

3. Wire mesh welding machine should be in the power after the maintenance and repair, workers should wear canvas gloves and around the work, so as not to burn.

4.Wire mesh welding machine can not be damp, to prevent leakage. If the machine long time no using then we must check whether the insulation resistance is qualified before the working, with 500V megger test welding machine power supply line and the insulation resistance between the shell shall be not less than 2.5 trillion euros can be used to power.

5. Wire mesh welding machine installation place should be no serious impact on the welding machine insulation properties such as corrosive gases, chemical deposits and corrosive, explosive, flammable media.

6. Wire mesh welding machine working time must be in strict accordance with the rated load duration work, overloading is prohibited. 

7. Water source treatment device of the water distribution filter must be frequent drainage, water level can not exceed the warning line, or the water will be compressed air into the atomizer and solenoid valve cylinder, causing the solenoid valve cylinder wear to speed up, or even not work properly.